| BASIC INFORMATION | ||
| Power Supply | V,Hz,Ph | 220-240V,1Ph,50Hz |
| Cooling | ||
| Capacity | Btu/h | 24000(6900-28700) |
| Input | W | 2170(700-2780) |
| Rated Current | A | 10(3.3-12.7) |
| EER | W/W | 3.24 |
| Heating | ||
| Capacity | Btu/h | 25000(7130-29700) |
| Input | W | 1910(570-2430) |
| Rated Current | A | 8.9(2.7-11.2) |
| COP | W/W | 3.84 |
| Max. Input Consumption | W | 2950 |
| Max. Current | A | 14.0 |
| Compressor | ||
| Model | ATF235D22UMT | |
| Type | Rotary | |
| Brand | GMCC | |
| Capacity | Btu/h | 24345 |
| Input | W | 1970 |
| Rated Current (RLA) | A | 6.95 |
| Refrigerant oil | ml | POE(VG74)/670 |
| SPECIFICATIONS | ||
| Refrigerant Type | Kg | R410A/1.95 |
| Design Pressure | MPa | 4.2/1.5 |
| Drainage Water Pipe Diameter | mm | ODΦ25 |
| Refrigerant Piping | ||
| Liquid Side/ Gas Side | mm(inch) | Φ9.52/Φ15.9(3/8″/5/8″) |
| Max. Refrigerant Pipe Length | m | 50 |
| Max. Difference In Level | m | 25 |
| Controller | KJR-120C1/BTF-E(AU) | |
| Operation Temperature | ℃ | 17-30 |
| Room Temperature | ||
| Indoor(Cooling/ Heating) | ℃ | 17~32/0~30 |
| Ambient Temperature | ||
| Outdoor(Cooling/ Heating) | ℃ | -15~50/-15~24 |
| INDOOR UNIT | ||
| Indoor Fan Motor | ||
| Model | ZKFN-160-8-1-2 | |
| Qty | 1 | |
| Input | W | 90 |
| Capacitor | uF | – |
| Speed(Hi/Mi/Lo) | r/min | 1010/950/890 |
| Indoor Coil | ||
| Number Of Rows | 3 | |
| Tube pitch(a)x row pitch(b) | mm | 21×13.37 |
| Fin Spacing | mm | 1.4 |
| Fin type (code) | Hydrophilic Aluminum | |
| Tube outside dia.and type | mm | Φ7.innergroove tube |
| Coil length x height x width | mm | 915x294x40.11 |
| Number Of Circuits | 7 | |
| Indoor air flow (Hi/Med/Lo) | m3/h | 1100/780/490 |
| ESP | ||
| Rated | Pa | 25 |
| Range | Pa | 0-100 |
| Indoor Noise Level (Hi/Med/Lo) | dB(A) | 41.5/39/36 |
| Indoor Unit | ||
| Dimension(W*D*H) | mm | 1100x774x249 |
| Packing (W*D*H) | mm | 1305x805x305 |
| Net Weight | Kg | 31.7 |
| Gross Weight | Kg | 39.1 |
| Container Loading 20′ feet | Unit | 77 |
| Container Loading 40′ feet | Unit | 161 |
| Container Loading 40′ feet High | Unit | 184 |
| OUTDOOR UNIT | ||
| Outdoor Fan Motor | ||
| Model | ZKFN-50-8-2 | |
| Qty | 1 | |
| Input | W | 115 |
| Capacitor | uF | – |
| Speed | r/min | 760 |
| Outdoor Coil | ||
| Number Of Rows | 2 | |
| Tube pitch(a)x row pitch(b) | mm | 25.4×22 |
| Fin Spacing | mm | 1.4 |
| Fin type (code) | Hydrophilic Aluminum | |
| Tube outside dia.and type | mm | Φ9.52,innergroove tube |
| Coil length x height x width | mm | 730x660x44 |
| Number Of Circuits | 4 | |
| Outdoor Air Flow | m3/h | 2700 |
| Outdoor Noise Level (Sound Pressure) | dB(A) | 60.5 |
| Throttle Type | Capillary + EXV | |
| Outdoor Unit | ||
| Dimension(WxDxH) | mm | 845x363x702 |
| Packing (W*D*H) | mm | 965x395x765 |
| Net Weight | Kg | 49 |
| Gross Weight | Kg | 51.5 |
| Container Loading 20′ feet | Unit | 102 |
| Container Loading 40′ feet | Unit | 216 |
| Container Loading 40′ feet High | Unit | 216 |








Reviews