| BASIC INFORMATION | ||
| Power Supply | V,Hz,Ph | 220-240V,1Ph,50Hz |
| Cooling | ||
| Capacity | Btu/h | 36000(9400–40600) |
| Input | W | 3250(1070-4060) |
| Rated Current | A | 14.9(5.0-18.7) |
| EER | W/W | 3.25 |
| Heating | ||
| Capacity | Btu/h | 41000(11900-48900) |
| Input | W | 3180(1020-3980) |
| Rated Current | A | 14.6 |
| COP | W/W | 3.78 |
| Max. Input Consumption | W | 4500 |
| Max. Current | A | 21 |
| Compressor | ||
| Model | ATF310D43UMT | |
| Type | Rotary | |
| Brand | GMCC | |
| Capacity | Btu/h | 32380 |
| Input | W | 2600 |
| Rated Current (RLA) | A | 5.10 |
| Refrigerant oil | ml | PQE(VG74)/1000 |
| SPECIFICATIONS | ||
| Refrigerant Type | Kg | R410A/3.2 |
| Design Pressure | MPa | 4.2/1.5 |
| Drainage Water Pipe Diameter | mm | ODΦ25 |
| Refrigerant Piping | ||
| Liquid Side/ Gas Side | mm(inch) | Φ9.52/Φ15.9(3/8″/5/8″) |
| Max. Refrigerant Pipe Length | m | 65 |
| Max. Difference In Level | m | 30 |
| Controller | KJR-120C1/BTF-E(AU) | |
| Operation Temperature | ℃ | 17-30 |
| Room Temperature | ||
| Indoor(Cooling/ Heating) | ℃ | 17~32/0~30 |
| Ambient Temperature | ||
| Outdoor(Cooling/ Heating) | ℃ | -15~50/-15~24 |
| INDOOR UNIT | ||
| Indoor Fan Motor | ||
| Model | ZKFN-300-8-1 | |
| Qty | 1 | |
| Input | W | 250/182/130 |
| Capacitor | uF | – |
| Speed(Hi/Mi/Lo) | r/min | 1100/1000/900 |
| Indoor Coil | ||
| Number Of Rows | 4 | |
| Tube pitch(a)x row pitch(b) | mm | 21×13.37 |
| Fin Spacing | mm | 1.4 |
| Fin type (code) | Hydrophilic Aluminum | |
| Tube outside dia.and type | mm | Φ7.innergroove tube |
| Coil length x height x width | mm | 1175x294x53.48 |
| Number Of Circuits | 7 | |
| Indoor air flow (Hi/Med/Lo) | m3/h | 1400/1150/750 |
| ESP | ||
| Rated | Pa | 37 |
| Range | Pa | 0-120 |
| Indoor Noise Level (Hi/Med/Lo) | dB(A) | 42/40.5/39 |
| Indoor Unit | ||
| Dimension(WxDxH) | mm | 1360x774x249 |
| Packing (WxDxH) | mm | 1570x805x305 |
| Net Weight | Kg | 40.5 |
| Gross Weight | Kg | 48.5 |
| Container Loading 20′ feet | Unit | 49 |
| Container Loading 40′ feet | Unit | 105 |
| Container Loading 40′ feet High | Unit | 120 |
| OUTDOOR UNIT | ||
| Outdoor Fan Motor | ||
| Model | ZKFN-120-8-2 | |
| Qty | 1 | |
| Input | W | 150 |
| Capacitor | uF | – |
| Speed | r/min | 950 |
| Outdoor Coil | ||
| Number Of Rows | 2 | |
| Tube pitch(a)x row pitch(b) | mm | 25.4×22 |
| Fin Spacing | mm | 1.3 |
| Fin type (code) | Hydrophilic Aluminum | |
| Tube outside dia.and type | mm | Φ9.52,innergroove tube |
| Coil length x height x width | mm | 995x762x44 |
| Number Of Circuits | 4 | |
| Outdoor Air Flow | m3/h | 4300 |
| Outdoor Noise Level (Sound Pressure) | dB(A) | 61 |
| Throttle Type | Capillary + EXV | |
| Outdoor Unit | ||
| Dimension(WxDxH) | mm | 946x410x810 |
| Packing (WxDxH) | mm | 1090x500x875 |
| Net Weight | Kg | 67.2 |
| Gross Weight | Kg | 72.9 |
| Container Loading 20′ feet | Unit | 44 |
| Container Loading 40′ feet | Unit | 96 |
| Container Loading 40′ feet High | Unit | 144 |








Reviews